Features & Benefits
- Port size 1/4 ISO G/NPT
- Reliable, rugged, open loop control;
- Proportional I/P nd E/P converters;
- Minimum vibration effects;
- IP65 environmental protection;
- Mounting bracket and connector included;
- ATEX certified units are available as intrinsically safe.
Technical Information
Medium: oil free, dry air, filtered to 5um
Output pressure:
100X:
- 0.2...1bar
- 3...15bar
- 3...27bar
101X
- 0.14...8bar
- 2...120bar
Supply pressure: at least 0.7bar above max. required output pressure. 5bar max
Flow capacity: >300Nl/min forward asnd relief flow
Air consumption:
- up to 1bar: 2.8Nl/min
- up to 2bar: 4.0Nl/min
Linearity: <0.5% of span
Hysteresis: <0.5% of span
Response time: <0.35s for 10...90% or 90...10% of output pressure into a 10cc load (1bar range instrument)
Temperature sensitivity: <0.1% of span/ degC between -40...85degC
Supply sensitivity: < 0.075% span output change per % supply pressure change
Port sizes:
- main ports: G1/4 or 1/4 NPT
- integral gauge ports: G1/4 or 1/4 NPT
Ambient/ Media temperature: -40...+85degC
air supply must be dry enough to avoid ice formation at temperatures below +2degC
I.P. Rating: IP65 in normal operation
Weight: 1kg
Mounting position: surface mounting bracket provided. alternative mounting options available
Vibration effect: 5% of span: 4mmp-p 5...15Hz and 2g sine 15...150Hz
Materials:
Body: passivated zinc die-casting, epoxy painted
Cover: glass reinforced nylon
Diaphragm: NBR