Features & Benefits
    • Port size: DN8...50, 1/4...2 (ISO G/NPT)
    • High flow rate; 
    • Damped operation; 
    • Functional compact design; 
    • Solenoid interchangeable without tools (Click-on®);
    • International approvals
    • Wide temperature range (-10…90degC); 

    Medium: Neutral gases and liquids
    Switching function: Normally closed
    Operation:Indirectly solenoid actuated
    Mounting position: Optional, preferably solenoid vertical on top
    Flow direction: Determined

    Port size: G1/4, G3/8, G1/2, G3/4, G1, G1 1/4, G1 1/2, G2 1/4 NPT, 3/8 NPT, 1/2 NPT 3/4 NPT, 1 NPT, 1 1/4 NPT, 1 1/2 NPT, 2 NPT
    Operating pressure: See table
    Differential pressure: 0,1 bar (1,45 psi) required

    Fluid temperature: -10 … +90°C (+14 … +194°F)
    Ambient temperature: –10 … +50°C (+14 … +122°F)

    Technical data

    Port  sizeOrificeValve lengthFlow kv value *1)Operating pressure *2)WeightModel
     (mm)(mm)(m3/h)(bar)(psi)(kg)Solenoid in V d.c./a.c.
    G1/48601,90,1 … 161,45 … 2320,478240000.9101.xxxxx
    1/4 NPT8601,90,1 … 161,45 … 2320,478241000.9101.xxxxx
    G3/8106030,1 … 161,45 … 2320,458240100.9101.xxxxx
    3/8 NPT106030,1 … 161,45 … 2320,458241100.9101.xxxxx
    G1/212673,80,1 … 161,45 … 2320,58240200.9101.xxxxx
    1/2 NPT12673,80,1 … 161,45 … 2320,58241200.9101.xxxxx
    G3/420806,10,1 … 161,45 … 2320,658240300.9101.xxxxx
    3/4 NPT20806,10,1 … 161,45 … 2320,658241300.9101.xxxxx
            
    G125959,50,1 … 161,45 … 2320,958240400.9101.xxxxx
    1 NPT25959,50,1 … 161,45 … 2320,958241400.9101.xxxxx
    G1 1/432132230,1 … 10 (16) *3)1,45 … 145 (232) *3)2,738240500.9101.xxxxx
    1 1/4 NPT32132230,1 … 10 (16) *3)1,45 … 145 (232) *3)2,738241500.9101.xxxxx
    G1 1/240132250,1 … 10 (16) *3)1,45 … 145 (232) *3)2,538240600.9101.xxxxx
    1 1/2 NPT40132250,1 … 10 (16) *3)1,45 … 145 (232) *3)2,538241600.9101.xxxxx
    G250160410,1 … 10 (16) *3)1,45 … 145 (232) *3)3,858240700.9101.xxxxx
    2 NPT50160410,1 … 10 (16) *3)1,45 … 145 (232) *3)3,858241700.9101.xxxxx

    xxxxx Please insert voltage and frequency codes
    *1) Cv-value (US) ≈ kv value x 1,2
    *2) For gases and liquid fluids up to 25 mm2/s (cSt)
    *3) With Solenoid 9151

    Standard solenoid systems

    Code VoltageCode FrequencyVoltageFrequencyPower consumption
      InrushHolding
    0240024 V d.c.-8 W8 W
    0245024 V a.c.50 Hz15 VA12 VA
    11050110 V a.c.50 Hz15 VA12 VA
    12060120 V a.c.60 Hz15 VA12 VA
    23050230 V a.c.50 Hz15 VA12 VA
    Voltage and Frequency Solenoid 9151 *4)
    0240024 V d.c.-18 W18 W
    0245024 V a.c.50 Hz45 VA35 VA
    11050110 V a.c.50 Hz45 VA35 VA
    12060120 V a.c.60 Hz45 VA35 VA
    23050230 V a.c.50 Hz45 VA35 VA
    Electrical details for all solenoid systems

    DesignDIN VDE 0580
    Voltage range±10%
    Duty cycle100% ED
    Protection classEN 60529 IP65

    According to DIN VDE 0580 at a solenoid temperature of +20°C.
    At operating state temperature the input power of a coil decreases by up to ca. 30% due to physical reasons.

    Additional solenoid systems for hazardous areas

    ATEX
    category
    ATEX
    protection class
    IP
    protection class
    SolenoidStandard voltages
    II 2G II 2DEx eb mb IIC T4 Gb
    Ex mb tb IIIB T125°C Db
    IP66610624 V d.c., 110 V a.c.,
    230 V a.c.
    II 2G II 2DEx eb mb IIC T4 Gb
    Ex mb tb IIIB T125°C Db
    IP666126 *5)24 V d.c., 110 V a.c.,
    230 V a.c.
    II 3G II 3DEx ec IIC T4 Gc
    Ex tc IIIC T130°C Dc
    IP65911624 V d.c., 110 V a.c.,
    230 V a.c.
    I 3G
    II 3D
    Ex ec IIC T4 Gc
    Ex tc IIIC T130°C Dc
    IP65917624 V d.c., 110 V a.c.,
    230 V a.c.

    Attention!
    The conditions imposed on the Ex approvals lead to reduction of the permissible standard temperature ranges in the cases of explosion protected solenoids.

    *5) from G1 1/4 / 1 1/4 NPT (16 bar))