Features & Benefits
    • Hole positions acc. to DIN 24340-D10-1 and ISO 5781-06-07-0-16
    • PN [pmax.] = 210 bar
    • Very good and delicate pressure setting
    • Pilot valve two varieties: manually operated and proportionally operated

    Medium: HLP, oil purity class according to ISO 4406: 20/18/15, other process liquids upon request
    Operation: Piston valve, directly actuated
    Actuation method: Pneumatic
    Mounting type: Flange
    Line connection: Subplate
    Nominal size: 10
    Operating pressure:
    Operating pressure range pe [bar]: 210
    Adjusted pressure range pv [bar]:
    min: 1 (type: D Y G 10 N A 63...)
    max: 70 (type: D Y G 10 N A 63...)
    min: 1 (type: D Y G 10 N A 74...)
    max: 140 (type: D Y G 10 N A 74...)
    min: 1 (type: D Y G 10 N A 80...)
    max: 210 (type: D Y G 10 N A 80...)
    Control oil return pipe X:
    pressure-less purging
    Pressure ratio PSt/pv=
    1/10 (type: D Y G 10 N A 63...)
    1/20 (type: D Y G 10 N A 74...) 
    1/30 (type: D Y G 10 N A 80...)
    Installation position: any
    Viscosity: 12 ...500 mm 2/s
    Flow: from B to A and A to Y
    Purge flow Qmax [l/min]: 70
    Pneumatic *1) Control pressure range PST [bar]: 0...7
    Fluid/Ambient temperature: 0 ... +70°C (+32 ... +158°F)
    Ambient temperature: 0 ... +50°C (+32 ... +122°F)
    Materials:
    Housing: Cast iron
    Piston slide valve: Hardened steel
    Seal: NBR
    End cover: Steel
    Roller diaphragm: Elastomer

     


    *1) As pneumatic control valve we recommend the manually operated fine pressure reducer, depending on the required adjusted pressure range or, if the electrical remote operation is required, we recommend the pneumatic proportional pressure regulation valves from our series 40 800 (see also 7502113) or the proportional pressure regulation valves with an integrated electronic pressure regulation (see also 7502094).