Features & Benefits
- Hole positions acc. to DIN 24340-D10-1 and ISO 5781-06-07-0-16
- PN [pmax.] = 210 bar
- Very good and delicate pressure setting
- Pilot valve two varieties: manually operated and proportionally operated
Technical Information
Medium: HLP, oil purity class according to ISO 4406: 20/18/15, other process liquids upon request
Operation: Piston valve, directly actuated
Actuation method: Pneumatic
Mounting type: Flange
Line connection: Subplate
Nominal size: 10
Operating pressure:
Operating pressure range pe [bar]: 210
Adjusted pressure range pv [bar]:
min: 1 (type: D Y G 10 N A 63...)
max: 70 (type: D Y G 10 N A 63...)
min: 1 (type: D Y G 10 N A 74...)
max: 140 (type: D Y G 10 N A 74...)
min: 1 (type: D Y G 10 N A 80...)
max: 210 (type: D Y G 10 N A 80...)
Control oil return pipe X:
pressure-less purging
Pressure ratio PSt/pv=
1/10 (type: D Y G 10 N A 63...)
1/20 (type: D Y G 10 N A 74...)
1/30 (type: D Y G 10 N A 80...)
Installation position: any
Viscosity: 12 ...500 mm 2/s
Flow: from B to A and A to Y
Purge flow Qmax [l/min]: 70
Pneumatic *1) Control pressure range PST [bar]: 0...7
Fluid/Ambient temperature: 0 ... +70°C (+32 ... +158°F)
Ambient temperature: 0 ... +50°C (+32 ... +122°F)
Materials:
Housing: Cast iron
Piston slide valve: Hardened steel
Seal: NBR
End cover: Steel
Roller diaphragm: Elastomer
*1) As pneumatic control valve we recommend the manually operated fine pressure reducer, depending on the required adjusted pressure range or, if the electrical remote operation is required, we recommend the pneumatic proportional pressure regulation valves from our series 40 800 (see also 7502113) or the proportional pressure regulation valves with an integrated electronic pressure regulation (see also 7502094).