Features & Benefits
- Hole positions acc. to DIN 243400-D10-1 and ISO 5781-06-07-0-16, PN(pmax.) = 315bar
- Simple electrical program and remote control
- Stable control characteristics
Technical Information
Medium: HLP, oil purity class according to ISO 4406: 20/18/15, other process liquids upon request
Operation: piston valve, indirectly controlled
Actuation method: proportional solenoid
Mounting type: Flange
Line connection: sub plate
Installation: on base plate
Nominal size:
10 (Type: D B S 10 UP G...)
25 (Type: D B S 25 UP G...)
Operating pressure:
operating pressure range pe: 315bar
Adjusted pressure range pv:
pv_min:10bar (at Q = 0 l/min)
pv_max: pressure rating 90: up to 315
Installation position: preferably solenoid suspended. during startup, vent the valve via the screw on the solenoid actuation system
Viscosity: 12...500mm2/s
Flow direction: from B to A and A to Y
Hysteresis: <4 %IN
Repetition accuracy: ca. +/-1% pv max.
Responsiveness: <1%IN
Absolute filtering: 25um
Fluid/Ambient temperatures: 0...+70degC
Ambient temperature: -20...+50degC
Circuit diagram: Herion
Materials:
- Housing: cast iron
- piston slide valve: hardened steel
- seal: NBR
- plate: steel