Features & Benefits
- Hole pattern according to DIN 24 340 and ISO 4401, PN max = 315bar
- Simple electrical program and remote control
- Outlet pressure stable even, when the inlet pressure changes
- External control oil drain upon request
Technical Information
Medium: HLP, other process liquids upon request
Operation: piston valve, indirectly controlled
Actuation method: proportional solenoid
Mounting type: Flange
Line connection: sub plate
Installation: on base plate
Nominal size: 6
Operating pressure:
operating pressure range pe: 330bar
Adjusted pressure range pv_max:
Pressure rating 50: up to 50
Pressure rating 70: ...100
Pressure rating 80: ...210
Pressure rating 90: ...315
Installation position: preferably solenoid suspended. during startup, vent the valve via the screw on the solenoid actuation system
Viscosity: 12...500mm2/s
Flow direction: from P to A and A to T
Regulating time for adjusted pressure range from pv min. up to pv max. at inlet pressure 210bar and Q=0: 70ms (for pressure rating 70)
Hysteresis: <4 %IN
Repetition accuracy: ca. +/-1% pv max.
Responsiveness: <1%IN
Filtering: oil purity class according to ISO 4406: 17/15/12
Fluid/Ambient temperatures: 0...+70degC
Ambient temperature: -20...+50degC
Circuit diagram: according to DIN 24340 and ISO 6264
Materials:
Housing: cast iron, thick layer passivated
piston slide valve: hardened steel
seal: NBR
plate: galvanised steel