Features & Benefits
- Plug-On amplifier for 1 proportional valve with one solenoid without feedback
- Directly plugs on to connector form “A” as per EN 175301-803-A / ISO 4400
- Very high max. output current of 3.5 A
- Fully digital PI current controller
- Supply voltage 12 V / 24 V DC
- Optional with CANopen interface
- Adaptation possible to all kinds of proportional valves from all manufacturers
- Analog input with high resolution and accuracy
- Very short cycle time for best dynamic behaviour (best in class)
- Easy usage and operation by means of program HSDC05Tool including oscilloscope function
Technical Information
Supply voltage: 12 VDC - 10 % .... 24 VDC + 20 %, Residual ripple < 10 % Supply current 10 mA @ 24 VDC (estimated, solenoid deactivated)
Solenoid system selection: 0,8 A; 1,1 A; 1,3 A; 1,6 A; 2,4 A; 2,7 A und 3,5 A (intermediate values adjustable)
Power input: max. 22 VA
Applicable fuse (quick): 2,5 A
IP Protection class: IP65
Protection class: III
Cable inlet: PG11 cable gland (connector and other on request)
Connection: Access by removing lid 5 / 7 screw terminals (7 terminals for CANopen version)
Insulator: PA 66; color green; Flammability Rating: UL94-V0
Metal housing: brass (CuZn);
Terminal screw: steel zinc plated, ”-” slot type
Contacts: brass; Current rating: 10 A; Contact resistance: 20 mOhm max
UL certified (E315414) and VDE certifeid (40024437)
Solid wire: 26 - 16 AWG / 0.129 - 1.31 mm²; Stranded: 26 - 16 AWG / 0.129 - 1.31 mm²
Torque: 3.5 lb/In - 0.4 Nm; Wire stripe length: 5 - 6 mm; Screw: M2,5, Pitch: 5.0 mm
Recommended cable for versions without CANopen:
4 strand 0.5 mm² (max length 20 m) shielded.
Lapp cable “ÖLFLEX® CLASSIC 115 CY” article number: 1136754
Analog set value:
Selection by means of parameter:
1 differential input, 12 Bit resolution, 0 … + 10 V; 0.5 V .... 9.5 V
or 0 / 4…20 mA @ 100 Ohm; cable fracture detection selectable where applicable
Solenoid output current:
1 output stage for up to 3.5 A; with over-energization
Interface for parameterization:
USB 2.0 interface with Micro USB connector
Recommended interface cable:
Digitus; USB 2.0, Stecker: 1 x USB type A, 1 x USB type Micro B, 1.8 m
Bus interface: CANopen
Recommended cable for versions with CANopen :
7 strand 0.5 mm² (max length 20 m) shielded.
Lapp cable “ÖLFLEX® CLASSIC 115 CY” article number: 1136757
Housing dimensions:
Approx. 104.0 x 44.5 x 59.0 mm (w x h x d) with PG11 cable gland
Approx. 78.0 x 44.5 x 59.0 mm (w x h x d) without PG11 cable gland
Housing material:
PA66-FR in accordance with UL94V0
Mounting:
Housing without ventilation for direct mounting on solenoids with connector form “A” as per EN 175301-803-A / ISO 4400 (ex DIN43650/A), quadratical form Please use attached seal between
solenoid and plug-on amplifier Gage glass for access and indication Gage glass with G1/4 thread for indication of status by LED Removable for access to USB 2.0 interface
EMC:
EMC in accordance with EN 61000-6-2: 2019 / EN 55011:2016 + A1:2017 class A and class B. EN 61000-6-4:2007 + A1:2011; EN 61000-6-3:2007 + A1:2011
Ambient operating temperature: - 40 °C to + 75 °C for solenoid currents up to 2,7 A and supply
voltage full range - 40 °C to + 60 °C for solenoid currents up to 3.5 A and supply voltage ≥ 24 V
Humidity (relative air humidity): max. 95 % non condensing
Storage temperature: - 45 °C to + 85 °C
Max. elevation: 2.000 m (mamsl)
Operation: By means of USB 2.0 and PC with HSDC05Tool Multi color status LED for indication
of power and status
PWM Frequency / Cycle time: 22 kHz / current controller and analog signal scan time approx. 0.045 mse