Features & Benefits
    • According to DIN 24 340 and ISO 4401 (CETOP05)
    • Speed and direction control according to setpoint specification
    • Program control, remote control
    • Analog interface for set point
    • Fast and si8mple configuration by PC with operating software (USB Adaption)

    Medium: HLP, oil purity class according to ISO 4406: 20/18/15, other process liquids upon request

    Operation: piston slide valve, directly actuated

    Installation: on base plate

    Nominal size: 10 

    Operating pressure: 

    connection P,A & B: 350bar max

    connection T 160bar max

    Installation position: preferably horizontal

    Viscosity: 12...500mm2/s

    Circuit diagram: according to DIN 24340 and ISO 4401 (CETOP05)

    Hysteresis: <5%

    Responsiveness: <0.1%

    Hysteresis error: <0.1%

    Zero flow at delta p 100bar without pressure maintenance valve cm3/min: <100

    Fluid temperatures: 0...+70degC

    Ambient temperature: -20...+50degC

    Materials:

    Housing: cast iron

    piston slide valve: hardened steel

    seal: FKM

    end cap: steel

    screws galvanised steel