Features & Benefits
    • Valve slices 2x3/2, 5/2 and 5/3 with integral push-in fittings dia3/4/6mm
    • Multipole or individually wired for installation flexib8ility
    • Interchangeable Fieldbus and Industrial Ethernet modules
    • Fieldbus options available - PROFIBUS DP, DeviceNET adn CANopen
    • industrial Ethernet options available - PROFINET IRT and EtherNet/IP
    • Fieldbus and Industrial Ethernet up to 16 stations (32 solenoids)
    • Compact and light weight
    • high flow from 10mm valve width

    Medium: compressed air, filtered, lubricated and non-lubricated

    Operations: spool valve indirectly actuated

    Port sizes: 3/4/6mm push-in fittings. Imperial versions also available

    Operating pressure: -0.9...8bar depending on pilot supply

    Flow:

    • 5/2 ports 1 to 2 & 1 to 4: 430l/min, Cv=0.44, Kv=0.36
    • 5/2 ports 2 to 3 & 4 to 5: 400l/min, Cv=0.41, Kv=0.34
    • 3/2 and 5/3: 350l/min, Cv=0.36, Kv=0.29

    Insulation protections:

    • Individually wired: IP40
    • Multipole, Fieldbus and Industrial Ethernet: IP65

    Ambient/ Media temperature: -5...+50degC (+23...+122F)

    air supply must be dry enough to avoid ice formation at temperature below +2degC (+35F)

    Materials:

    • Body, end plate: engineered PPA co-polymer
    • Spool: aluminum
    • Seals: NBR