Features & Benefits
    • Port size G1/4…3/4; 
    • Pressure range 0…2, 0…10 and 0…16bar.
    • Microprocessor-controlled close-loop control; 
    • Setpoint: 4 to 20mA, 0 to 10V, IO-Link; 

    Medium: filtered (50um), unlubricated or lubricated condensate-free compressed air or neutral gases. 

    Due to the lubricants and their additives, use of lubricated compressed air can affect the dynamics and service life

    Operations: proportional solenoid

    Pressure range

    • operating pressure P1 max: 7bar, 12bar, 17bar
    • operating pressure P2: 0...2/10/16bar

    Flow directions: 1 --> 2, 2-->3

    Service life: >10 million operations, max. stroke

    Linearity: <+/-1.0% (p2 max.)

    Control accuracy: <+/-1.0% (p2 max.)

    Response accuracy: <+/-0.2% (p2 max.)

    Hysteresis: <+/- 0.5% (p2 max.)

    Repeat accuracy: <+/- 0.5% (p2 max.) values related to 20degC and 24vdc power supply

    Ambient: valve series is designed for indoor use at normal industrial ambient

    Ambient temperature: -5...+60degC

    Media temperature: -5...+50degC

    air supply must be dry enough to avoid ice formation at temperatures below +2degC

    Materials: 

    valve housing: Aluminum

    Electronic housing: PAA

    Seals: NBR, HNBR on request

    Internal parts: PBT

    Spring: steel