Features & Benefits
- Nominal size: 8mm
- High flow rate - low pressure loss;
- Calibrated, linear flow characteristic with zero crossover;
- Variety of setpoint input: 4 to 20mA, 0 to 10V, ±5 V, IO-Link;
- Instant dynamic response.
Technical Information
Medium: air according to ISO8573-1 Grouping: 2-3-1, filtered (recommended <3um), dried, non lubricated.
Note: the dynamic performance and service life of the valve may be significantly reduced if using unfiltered air containing water and oil!
Operating pressure on all ports: -1...16bar
Pneumatical flow coeff.: C=290Nl/(min bar)
Critical pressure ratio: b = 0.1...0.4
Calibrated flow rate (Qmax): 1200Nl/min at P1 = 6bar,k P2, P4 = 5bar
imperial vals. for 8Nl/min -> 0.0081Cv
Leakage: typical value: 8Nl/min at (P1=10bar, P2/P4=0bar)
Port size: G1/4, 1/4NPT or flange mounted accordigng ISO 1
Spool deadtime: 3ms max
Rise time 10...90% = 5ms
Threashold frequency -3dB: 105Hz
Service life: >250 million full stroke operations with recommended air quality
Ambient temperature: 0...+60degC
Media temperature: +5...+60degC
Storage temperature: -20...+80degC
condensation not permitted!
air supply must be dry enough to avoid ice formation at temperatures below +2degC
Materials:
- Electronic enclosure: PAA
- valve housing and internal parts: anodised aluminum
- other static seals: NBR
- actuator magnet: Fe, surface refined